view this post on Zulip Lisa Nelson (May 08 2020 at 15:17):

I am reporting a problem that started about an hour ago:
This error was created by the template (00:20.0743)
IG Publisher finished with code 1
The HL7 IG Publisher failed. The HL7 IG Publisher tool is not developed as part of Trifolia-on-FHIR; it is developed by HL7. If you are still having issues after having reviewed and addressed ToF errors reported in the log above, go to chat.fhir.org to get more information on how to proceed.
I can't publish my IG in either the production or development version of Trifolia on FHIR. @Grahame Grieve

view this post on Zulip Lloyd McKenzie (May 08 2020 at 15:39):

"Error code 1" is not terribly helpful. Does Trifolia expose the build log?

view this post on Zulip Natasha Kreisle (May 08 2020 at 16:17):

When using the HL7 template, the IG id must start with "hl7." - found sdoh-uc2
[xslt] XXXXXX-1lJc6ikVGhaYj/template/scripts/onGenerate.genProperties.xslt:24: Fatal Error! Processing terminated by xsl:message at line 24 in onGenerate.genProperties.xslt
[xslt] Failed to process XXXXXX-1lJc6ikVGhaYj/template/onGenerate-ig-updated.xml
Publishing Content Failed: Fatal error during transformation using XXXXXX-1lJc6ikVGhaYj/template/scripts/onGenerate.genProperties.xslt: Processing terminated by xsl:message at line 24 in onGenerate.genProperties.xslt; SystemID: file:/tmp/tmp-1lJc6ikVGhaYj/template/scripts/onGenerate.genProperties.xslt; Line#: 24; Column#: -1 (00:19.0200)
(00:19.0201)
This error was created by the template (00:19.0202)
IG Publisher finished with code 1
The HL7 IG Publisher failed. The HL7 IG Publisher tool is not developed as part of Trifolia-on-FHIR; it is developed by HL7. If you are still having issues after having reviewed and addressed ToF errors reported in the log above, go to chat.fhir.org to get more information on how to proceed.

view this post on Zulip Sean McIlvenna (May 08 2020 at 17:38):

@Natasha Kreisle per the logs above, you need to set the "package id" of the implementation to something that starts with "hl7." in order to use the official hl7 template
When using the HL7 template, the IG id must start with "hl7." - found sdoh-uc2

view this post on Zulip Sean McIlvenna (May 08 2020 at 17:38):

You can change this in Browse/Edit > "Implementation Guide", on the "General" tab.
It is the field labeled "Package Id" on the right side of the screen.

view this post on Zulip Sean McIlvenna (May 08 2020 at 17:39):

perhaps "hl7.fhir.us.sdohuc2"

view this post on Zulip Sean McIlvenna (May 08 2020 at 17:39):

note that when you make that change, you will also have to specify the "HL7 Work Group" field