Keith Boone (Dec 12 2017 at 05:34):
Is there a way to comment on the Argonaut Data Query Implementation Guide Version 1.0.0 like there is on FHIR itself?
I'm concerned about the representation of Blood Pressure as component as specified herein: http://www.fhir.org/guides/argonaut/r2/StructureDefinition-argo-vitalsigns.html. Given that there are many panels that include blood pressure with multiple components, this results in a challenging representation and inconsistent method of access for specific coded concepts for our users.
Lloyd McKenzie (Dec 12 2017 at 06:24):
Submit a change request and set the spec to US-Core
Eric Haas (Dec 12 2017 at 16:35):
Submit a change request and set the spec to US-Core
That is for US Core.
Eric Haas (Dec 12 2017 at 16:35):
Don't submit for Argo there
Eric Haas (Dec 12 2017 at 16:36):
Here is a good place to start. Can you clarify what you mean. and give an example?
Eric Haas (Dec 12 2017 at 16:37):
We did not constrain the BP so that you can't add other components. It may be too constrained on type however...