FHIR Chat · Use of Cuff Size FHIR vital signs BP profile · implementers

Stream: implementers

Topic: Use of Cuff Size FHIR vital signs BP profile


view this post on Zulip Emma Jones (Nov 09 2020 at 13:41):

FHIR Vital Signs BP profile - http://hl7.org/fhir/R4/bp.html (snapshot view)- stipulates "For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." at observation.value.

  1. Please confirm this means another separate Observation just for cuff size is needed. If this is not the case, how are implementers implementing cuff size along with BP measurements?
  2. Are folks implementing cuff size in the same BP Observation at Observation.valueCodeableConcept?
  3. Please provide an example if possible
    Thanks.

view this post on Zulip Michele Mottini (Nov 09 2020 at 14:01):

Cuff size cannot be in the same BP observation because an observation can have only one value, it must be a separate observation or maybe a component of the BP observation

view this post on Zulip Lin Zhang (Nov 09 2020 at 14:14):

Maybe this LOINC Panel could be used to represent the bp and related obsevations, including the cuff size: https://loinc.org/35094-2/

view this post on Zulip Eric Haas (Nov 09 2020 at 15:37):

look at the vitals panel page for guidance:http://build.fhir.org/observation-vitalsigns.html

view this post on Zulip Eric Haas (Nov 09 2020 at 15:38):

it's a component

view this post on Zulip Lloyd McKenzie (Nov 09 2020 at 19:11):

It's a component because it's not meaningful on its own - it's a qualifier of the blood pressure observation


Last updated: Apr 12 2022 at 19:14 UTC