Samantha Mater (Oct 15 2018 at 22:41):
How is it expected that we represent three different implants with the same UDI (like screws) implanted in the same location? Would that be three separate but identical resources?
Lloyd McKenzie (Oct 15 2018 at 23:38):
Yes
Lloyd McKenzie (Oct 15 2018 at 23:39):
In theory, the implementation time could differ by a few seconds and the placement would also be sufficiently different - so "exactly the same" would depend on the granularity you use to capture the information
Christopher Kundra (Oct 31 2018 at 19:11):
I have this question too. Does anybody have any advice? Thanks!
Christopher Kundra (Oct 31 2018 at 19:13):
Never mind, I didn't see your reply Lloyd. Sorry!
Jose Costa Teixeira (Nov 05 2018 at 20:12):
@Lloyd McKenzie this is one of the things for a xxxInstance (not necessarily a resource, but some content that says "if this contains any data, then you know it is a physical thing).
Jose Costa Teixeira (Nov 05 2018 at 20:16):
not to restart that discussion, just connecting the dots.