FHIR Chat · HL7 vital signs headcircum code · implementers

Stream: implementers

Topic: HL7 vital signs headcircum code


view this post on Zulip Sebastiaan Raap (Apr 01 2019 at 13:48):

Hi guys,

I have a question about the HL7 vital signs profile "headCircum". The code.coding slice has a fixed LOINC code 8287-5 which means “Head Occipital-frontal circumference by Tape measure.”

This LOINC code states that the observation is done by a Tape measure. Which excludes measurements by other methods like ultrasound in an obstetric setting e.g.

A more general LOINC code is available, namely 9843-4 - Head Occipital-frontal circumference. Is this code not a better fit? The Observation.method could hold the information on the method used for the observation.

Thanks!

view this post on Zulip Lloyd McKenzie (Apr 01 2019 at 14:09):

@Eric Haas

view this post on Zulip Eric Haas (Apr 01 2019 at 20:30):

like here? http://build.fhir.org/headcircum.html

view this post on Zulip Eric Haas (Apr 01 2019 at 20:31):

already updated in R4...


Last updated: Apr 12 2022 at 19:14 UTC