Bryn Rhodes (Oct 06 2017 at 22:29):
In the QI-Core IG, we have 2 errors that are a result of the IG publisher not being able to resolve the URL for the value set reference to a binding to a US-Core value set. The canonical URL for the ValueSet, as listed on the US Core page is http://hl7.org/fhir/us/core/ValueSet/us-core-procedure-code, which is what we have listed as the valueSetReference for the binding in the profile. However, the IG publisher is giving: Unable to resolve resource 'http://hl7.org/fhir/us/core/ValueSet/us-core-procedure-code'. Are we referencing the value set incorrectly?
Bryn Rhodes (Oct 12 2017 at 22:16):
Here's the error from the qa.html of the build:
Bryn Rhodes (Oct 12 2017 at 22:16):
StructureDefinition/qicore-procedure: StructureDefinition.snapshot.element[20].binding.valueSetReference
error
Unable to resolve resource 'http://hl7.org/fhir/us/core/ValueSet/us-core-procedure-code'
Christopher Schuler (Oct 17 2017 at 20:23):
I believe that I have discovered the issue with us-core-procedure code valueset. There is an expansion error with the cpt codesystem (see here at bottom of the page: http://build.fhir.org/ig/HL7/US-Core/ValueSet-us-core-procedure-code.html). The other valuesets that resolve successfully don't have this error. @Eric Haas Does my assessment sound right and is it possible to fix?
Eric Haas (Oct 17 2017 at 21:00):
Unless things have changed recently that is an IP issue with AMA and CPT codes - we can't expand them without paying.
Grahame Grieve (Oct 17 2017 at 21:52):
yep. AMA have refused to collaborate